Abstract
Quantitative measurements used in nuclear medicine imaging are becoming increasingly decisive in disease detection, staging, and treatment response evaluation. This review addresses harmonization and synthetic data use, which increase the reliability and generalizability of numerical measurements and artificial intelligence (AI) models. The first section addresses harmonization. Differences in technical characteristics and imaging protocols between centers, or between devices within the same center, make numerical data difficult to compare. This causes non-biological artificial variations in multicenter studies. Harmonization strategies fall into two groups: image-based corrections, and statistical correction of numerical data. In image corrections, center effects are reduced using internationally accepted standards and phantoms. In statistical corrections, the ComBat method and its improved versions are commonly preferred. In recent years, AI methods have also been incorporated into harmonization. Studies show harmonization increases AI models’ success in disease classification and survival prediction, with more consistent results. The second section focuses on synthetic data. Access to quality, large datasets required by AI models is restricted by patient privacy, rare disease scarcity, and radiation exposure. Synthetic data technologies offer an innovative solution: data created by imitating the distribution of real data using mathematical models and algorithms. Deep learning architectures such as generative adversarial networks, variational autoencoders, vision transformer, and denoising diffusion models enable quality synthetic medical images. These images are used to expand AI training sets, improve diagnostic quality of low-dose or short-duration scans, and perform cross-modality image conversion for attenuation correction in hybrid systems. In conclusion, harmonization methods and synthetic data generation approaches, as mutually reinforcing strategic building blocks, carry potential to increase AI model reliability in nuclear medicine. Addressing both approaches in an integrated manner will lay groundwork for standardizing next-generation diagnostic and treatment monitoring protocols in imaging. However, using these methods in clinical practice requires support from comprehensive studies.
Keywords: Harmonization, synthetic data, emission tomography, artificial intelligence
References
Akamatsu G, Tsutsui Y, Daisaki H, Mitsumoto K, Baba S, Sasaki M. A review of harmonization strategies for quantitative PET. Ann Nucl Med. 2023;37:71-88.
Matsuda H, Murata M, Mukai Y, et al. Japanese multicenter database of healthy controls for [123I]FP-CIT SPECT. Eur J Nucl Med Mol Imaging. 2018;45:1405-1416.
Kaalep A, Sera T, Oyen W, et al. EANM/EARL FDG-PET/CT accreditation - summary results from the first 200 accredited imaging systems. Eur J Nucl Med Mol Imaging. 2018;45:412-422.
Sunderland JJ, Boellaard R, Dickson JC, Graves SA, Bailey DL. Standardization of PET/CT performance requirements for whole-body quantitative imaging: an international proposal. J Nucl Med. 2025;66:1506-1515.
Koetzier LR, Wu J, Mastrodicasa D, et al. Generating Synthetic Data for Medical Imaging. Radiology. 2024;312:e232471.
Karmakar A, Shaw A, Rakshit S, et al. The role of generative AI in medical image synthesis: a review. Discov Appl Sci. 2025;7:1219.
Joshi A, Koeppe RA, Fessler JA. Reducing between scanner differences in multi-center PET studies. Neuroimage. 2009;46:154-159.
Orlhac F, Boughdad S, Philippe C, et al. A postreconstruction harmonization method for multicenter radiomic studies in PET. J Nucl Med. 2018;59:1321-1328.
Orlhac F, Eertink JJ, Cottereau AS, et al. A guide to ComBat harmonization of imaging biomarkers in multicenter studies. J Nucl Med. 2022;63:172-179.
Mali SA, Ibrahim A, Woodruff HC, et al. Making radiomics more reproducible across scanner and imaging protocol variations: a review of harmonization methods. J Pers Med. 2021;11:842.
Kaalep A, Sera T, Rijnsdorp S, et al. Feasibility of state of the art PET/CT systems performance harmonisation. Eur J Nucl Med Mol Imaging. 2018;45:1344-1361.
Shekari M, Verwer EE, Yaqub M, et al.; AMYPAD Consortium. Harmonization of brain PET images in multi-center PET studies using Hoffman phantom scan. EJNMMI Phys. 2023;10:68.
Panetta JV, Daube-Witherspoon ME, Karp JS. Validation of phantom-based harmonization for patient harmonization. Med Phys. 2017;44:3534-3544.
Daisaki H, Kitajima K, Nakajo M, et al. Usefulness of semi-automatic harmonization strategy of standardized uptake values for multicenter PET studies. Sci Rep. 2021;11:8517.
Monsef A, Ay MR, Sheikhzadeh P, Geramifar P, Rahmim A, Ghafarian P. Harmonization based on quantitative analysis of standardized uptake value variations across PET/CT scanners: a multicenter phantom study. Nucl Med Commun. 2022;43:1004-1014.
Dudasova K, Trnka J. Towards prediction of pseudo-normal SPECT image data using variational autoencoder. Nucl Med Rev Cent East Eur. 2025;28:9-17.
Haberl D, Spielvogel CP, Jiang Z, et al. Multicenter PET image harmonization using generative adversarial networks. Eur J Nucl Med Mol Imaging. 2024;51:2532-2546.
Shah J, Che Y, Sohankar J, et al. For The Alzheimer’s Disease Neuroimaging Initiative. Enhancing amyloid PET quantification: MRI-guided super-resolution using latent diffusion models. Life (Basel). 2024;14:1580.
Kang SK, Choi H, Lee JS; Alzheimer’s Disease Neuroimaging Initiative. Translating amyloid PET of different radiotracers by a deep generative model for interchangeability. Neuroimage. 2021;232:117890.
Sanaat A, Shooli H, Böhringer AS, et al. A cycle-consistent adversarial network for brain PET partial volume correction without prior anatomical information. Eur J Nucl Med Mol Imaging. 2023;50:1881-1896.
Johnson WE, Li C, Rabinovic A. Adjusting batch effects in microarray expression data using empirical Bayes methods. Biostatistics. 2007;8:118-127.
Fortin JP, Cullen N, Sheline YI, et al. Harmonization of cortical thickness measurements across scanners and sites. Neuroimage. 2018;167:104-120.
Wakasugi N, Takano H, Abe M, et al.; Parkinson’s and Alzheimer’s disease Dimensional Neuroimaging Initiative (PADNI). Harmonizing multisite data with the ComBat method for enhanced Parkinson’s disease diagnosis via DAT-SPECT. Front Neurol. 2024;15:1306546.
Da-Ano R, Lucia F, Masson I, et al. A transfer learning approach to facilitate ComBat-based harmonization of multicentre radiomic features in new datasets. PLoS One. 2021;16:e0253653.
Da-Ano R, Masson I, Lucia F, et al. Performance comparison of modified ComBat for harmonization of radiomic features for multicenter studies. Sci Rep. 2020;10:10248.
Hu F, Lucas A, Chen AA, et al.; Alzheimer’s Disease Neuroimaging Initiative. DeepComBat: a statistically motivated, hyperparameter-robust, deep learning approach to harmonization of neuroimaging data. Hum Brain Mapp. 2024;45:e26708.
Wang B, Liu J, Zhang X, et al. Residual conditional variational autoencoder for multi-center PET/CT radiomic feature harmonization with integrated modeling of batch effects and clinical covariates. J Imaging Inform Med. 2026. [Epub Ahead of Print].
Hosseini SA, Shiri I, Ghaffarian P, et al. The effect of harmonization on the variability of PET radiomic features extracted using various segmentation methods. Ann Nucl Med. 2024;38:493-507.
Shiri I, Amini M, Nazari M, et al. Impact of feature harmonization on radiogenomics analysis: Prediction of EGFR and KRAS mutations from non-small cell lung cancer PET/CT images. Comput Biol Med. 2022;142:105230.
Dwivedi P, Barage S, Singh R, et al. PET-based radiomic analysis in multicentre lung cancer study and impact of feature domain harmonization. Phys Eng Sci Med. 2025;48:1841-1851.
Wu H, Liu X, Peng L, et al. Optimal batch determination for improved harmonization and prognostication of multi-center PET/CT radiomics feature in head and neck cancer. Phys Med Biol. 2023;68:225014.
Shiri I, Amini M, Hajianfar G, et al. On the removal of inter/intra observer variability of PET radiomics features. In: Tomita H, Nakamura T, editors. 2021 IEEE Nuclear Science Symposium and Medical Imaging Conference Record, NSS/MIC 2021 and 28th International Symposium on Room-Temperature Semiconductor Detectors, RTSD 2022. IEEE; 2022.
Patel P. Synthetic data. Business Information Review. 2024;41:48-52.
Jordon J, Szpruch L, Houssiau F, et al. Synthetic data—what, why and how? arXiv; 2022.
Bluethgen C, Chambon P, Delbrouck JB, et al. A vision-language foundation model for the generation of realistic chest X-ray images. Nat Biomed Eng. 2025;9:494-506.
Khosravi B, Li F, Dapamede T, et al. Synthetically enhanced: unveiling synthetic data’s potential in medical imaging research. EBioMedicine. 2024;104:105174.
Pinaya WH, Tudosiu PD, Dafflon J, et al. Brain imaging generation with latent diffusion models. In: Mukhopadhyay A, Oksuz I, Engelhardt S, Zhu D, Yuan Y, editors. Deep Generative Models. Cham: Springer; 2022.
Khosravi B, Purkayastha S, Erickson BJ, Trivedi HM, Gichoya JW. Exploring the potential of generative artificial intelligence in medical image synthesis: opportunities, challenges, and future directions. Lancet Digit Health. 2025:100890.
Dayarathna S, Islam KT, Uribe S, Yang G, Hayat M, Chen Z. Deep learning based synthesis of MRI, CT and PET: review and analysis. Med Image Anal. 2024;92:103046.
Goodfellow I, Pouget-Abadie J, Mirza M, et al. Generative adversarial networks. Commun ACM. 2020;63:139-144.
Apostolopoulos ID, Papathanasiou ND, Apostolopoulos DJ, Panayiotakis GS. Applications of generative adversarial networks (GANs) in positron emission tomography (PET) imaging: a review. Eur J Nucl Med Mol Imaging. 2022;49:3717-3739.
Kingma DP, Welling M. Auto-encoding variational Bayes. arXiv; 2013.
Ho J, Jain A, Abbeel P. Denoising diffusion probabilistic models. In: Advances in Neural Information Processing Systems. 2020;33:6840-6851.
Alshanbari AH, Alzahrani SM. Generative AI for diagnostic medical imaging: a review. Curr Med Imaging. 2025;21:e15734056369157.
Vaccaro M, Rosa E, Placidi E, et al. Deep learning for synthetic PET imaging: a systematic mapping review of techniques, metrics, and clinical relevance. Eur Radiol Exp. 2026;10:12.
Liu Z, Wolfe S, Yu Z, et al. Observer-study-based approaches to quantitatively evaluate the realism of synthetic medical images. Phys Med Biol. 2023;68:074001.
Chlap P, Min H, Vandenberg N, Dowling J, Holloway L, Haworth A. A review of medical image data augmentation techniques for deep learning applications. J Med Imaging Radiat Oncol. 2021;65:545-563.
Amirrajab S, Al Khalil Y, Lorenz C, Weese J, Pluim J, Breeuwer M. Label-informed cardiac magnetic resonance image synthesis through conditional generative adversarial networks. Comput Med Imaging Graph. 2022;101:102123.
Kim BN, Dolz J, Jodoin PM, Desrosiers C. Privacy-Net: an adversarial approach for identity-obfuscated segmentation of medical images. IEEE Trans Med Imaging. 2021;40:1737-1749.
Cohen JP, Brooks R, En S, et al. Gifsplanation via latent shift: a simple autoencoder approach to counterfactual generation for chest X-rays. In: Heinrich M, Dou Q, de Bruijne M, Lellmann J, Schläfer A, Ernst F, editors. Proceedings of the Fourth Conference on Medical Imaging with Deep Learning. PMLR. 2021;143:74-104. Available from: https://proceedings.mlr.press/v143/cohen21a.html
Balaji V, Song TA, Malekzadeh M, Heidari P, Dutta J. Artificial intelligence for PET and SPECT image enhancement. J Nucl Med. 2024;65:4-12.
Islam J, Zhang Y. GAN-based synthetic brain PET image generation. Brain Inform. 2020 Mar 30;7(1):3.
Sohn B, Chung SJ, Lee JR, et al.; Harvard Brain Imaging Study; Japanese Alzheimer’s Disease Neuroimaging Initiative; Alzheimer’s Disease Neuroimaging Initiative. 18F-FDG-PET-based deep learning for predicting cognitive decline in non-demented elderly across the Alzheimer’s disease clinical spectrum. Radiol Adv. 2024;1:umae021.
Jeong YJ, Park HS, Jeong JE, et al. Restoration of amyloid PET images obtained with short-time data using a generative adversarial networks framework. Sci Rep. 2021;11:4825.
Armanious K, Hepp T, Küstner T, et al. Independent attenuation correction of whole body [18F]FDG-PET using a deep learning approach with Generative Adversarial Networks. EJNMMI Res. 2020;10:53.
Hu Z, Li Y, Zou S, et al. Obtaining PET/CT images from non-attenuation corrected PET images in a single PET system using Wasserstein generative adversarial networks. Phys Med Biol. 2020;65:215010.
Hu S, Lei B, Wang S, Wang Y, Feng Z, Shen Y. Bidirectional Mapping Generative Adversarial Networks for Brain MR to PET Synthesis. IEEE Trans Med Imaging. 2022;41:145-157.


