The Role of Artificial Intelligence in Theranostic and Dosimetry Applications in Nuclear Medicine
PDF

Review

The Role of Artificial Intelligence in Theranostic and Dosimetry Applications in Nuclear Medicine

Nucl Med Semin 2026;12(3):208-214 DOI: 10.4274/nts.galenos.2026.69885
PDF
Permissions

Abstract

With the clinical integration of modern molecular imaging modalities, the volume and complexity of data generated in nuclear medicine have increased rapidly. Implementing artificial intelligence (AI) in the theranostic workflow offers the potential for comprehensive automation across patient selection, image interpretation, organ and tumor segmentation, personalized dosimetry, and treatment response monitoring. AI algorithms can support the evaluation of diagnostic molecular imaging data and the development of post-treatment personalized dosimetry. This review examines the role of AI in theranostic imaging, automated segmentation, accelerated voxel-level dosimetry, predictive dosimetry, and adaptive treatment planning.

Keywords: Artificial intelligence, deep learning, theranostics, radiopharmaceutical therapy, radiation dosimetry

References

1

Wibmer AG, Hricak H, Ulaner GA, Weber W. Trends in oncologic hybrid imaging. Eur J Hybrid Imaging. 2018;2:1.

2

Saboury B, Bradshaw T, Boellaard R, et al. Artificial intelligence in nuclear medicine: opportunities, challenges, and responsibilities toward a Trustworthy Ecosystem. J Nucl Med. 2023;64:188-196.

3

Belge Bilgin G, Bilgin C, Burkett BJ, et al. Theranostics and artificial intelligence: new frontiers in personalized medicine. Theranostics. 2024;14:2367-2378.

4

Jha AK, Bradshaw TJ, Buvat I, et al. Nuclear medicine and artificial intelligence: best practices for evaluation (the RELAINCE guidelines). J Nucl Med. 2022;63:1288-1299.

5

Brosch-Lenz JF, Delker A, Schmidt F, Tran-Gia J. On the use of artificial intelligence for dosimetry of radiopharmaceutical therapies. Nuklearmedizin. 2023;62:379-388.

6

Rydén T, Van Essen M, Marin I, Svensson J, Bernhardt P. Deep-learning generation of synthetic intermediate projections improves 177Lu SPECT images reconstructed with sparsely acquired projections. J Nucl Med. 2021;62:528-535.

7

Currie GM, Rohren E. The role of artificial intelligence in theranostics. J Nucl Med Technol. 2025;53(Suppl 1):82S-91S.

8

Chaudhari AS, Mittra E, Davidzon GA, et al. Low-count whole-body PET with deep learning in a multicenter and externally validated study. NPJ Digit Med. 2021;4:127. Erratum in: NPJ Digit Med. 2021;4:139.

9

Bradshaw TJ, Boellaard R, Dutta J, et al. Nuclear medicine and artificial intelligence: best practices for algorithm development. J Nucl Med. 2022;63:500-510.

10

Pan S, Abouei E, Peng J, et al. Full-dose whole-body PET synthesis from low-dose PET using high-efficiency denoising diffusion probabilistic model: PET consistency model. Med Phys. 2024;51:5468-5478.

11

Dexl J, Gatidis S, Früh M, et al. AutoPET Challenge on fully automated lesion segmentation in oncologic PET/CT imaging, part 2: domain generalization. J Nucl Med. 2026;67:481-488.

12

Xia M, Bayerlein R, Chemli Y, et al. On hallucinations in artificial intelligence-generated content for nuclear medicine imaging (the DREAM report). J Nucl Med. 2026;67:166-174.

13

Dong X, Lei Y, Wang T, et al. Deep learning-based attenuation correction in the absence of structural information for whole-body positron emission tomography imaging. Phys Med Biol. 2020;65:055011.

14

Hosono M, Takenaka M, Monzen H, Tamura M, Kudo M, Nishimura Y. Cumulative radiation doses from recurrent PET-CT examinations. Br J Radiol. 2021;94:20210388.

15

Liu F, Jang H, Kijowski R, Bradshaw T, McMillan AB. Deep learning MR imaging-based attenuation correction for PET/MR imaging. Radiology. 2018;286:676-684.

16

Wyatt JJ, Kaushik S, Cozzini C, et al. Evaluating a radiotherapy deep learning synthetic CT algorithm for PET-MR attenuation correction in the pelvis. EJNMMI Phys. 2024;11:10.

17

Kurkowska S, Dewaraja YK, Frey EC, Brosch-Lenz J, Sunderland J, Uribe C. An international study of factors affecting variability of dosimetry calculations, part 5: impact of segmentation methods. EJNMMI Phys. 2026;13:39.

18

Lopes L, Lopez-Montes A, Chen Y, et al. The evolution of artificial intelligence in nuclear medicine. Semin Nucl Med. 2025;55:313-327.

19

Kostyszyn D, Fechter T, Bartl N, et al. Intraprostatic tumor segmentation on PSMA PET images in patients with primary prostate cancer with a convolutional neural network. J Nucl Med. 2021;62:823-828.

20

Nickols N, Anand A, Johnsson K, et al. aPROMISE: a novel automated PROMISE platform to standardize evaluation of tumor burden in 18F-DCFPyL images of veterans with prostate cancer. J Nucl Med. 2022;63:233-239.

21

Johnsson K, Brynolfsson J, Sahlstedt H, et al. Analytical performance of aPROMISE: automated anatomic contextualization, detection, and quantification of [18F]DCFPyL (PSMA) imaging for standardized reporting. Eur J Nucl Med Mol Imaging. 2022;49:1041-1051.

22

Arias-Londoño JD, Godino-Llorente JI. Analysis of the Clever Hans effect in COVID-19 detection using chest X-Ray images and Bayesian deep learning. Biomedical Signal Processing and Control. 2024;90:105831.

23

Sjögreen-Gleisner K, Rueckert D, Ljungberg M. Registration of serial SPECT/CT images for three-dimensional dosimetry in radionuclide therapy. Phys Med Biol. 2009;54:6181-6200.

24

Oh S, Kim S. Deformable image registration in radiation therapy. Radiat Oncol J. 2017;35:101-111.

25

Grassi E, Fioroni F, Berenato S, et al. Effect of image registration on 3D absorbed dose calculations in 177Lu-DOTATOC peptide receptor radionuclide therapy. Phys Med. 2018;45:177-185.

26

O’Donoghue J, Zanzonico P, Humm J, Kesner A. Dosimetry in radiopharmaceutical therapy. J Nucl Med. 2022;63:1467-1474.

27

Sarrut D, Arbor N, Baudier T, et al. The OpenGATE ecosystem for Monte Carlo simulation in medical physics. Phys Med Biol. 2022;67:184001.

28

Kontaxis C, Bol GH, Lagendijk JJW, Raaymakers BW. DeepDose: towards a fast dose calculation engine for radiation therapy using deep learning. Phys Med Biol. 2020;65:075013.

29

Hobbs RF, Song H, Watchman CJ, et al. A bone marrow toxicity model for 223Ra alpha-emitter radiopharmaceutical therapy. Phys Med Biol. 2012;57:3207-3222.

30

Banala M, Ezuddin S, Foley M, Kuker R. Artificial intelligence across oncologic theranostics: evidence for patient stratification, dosimetry, and adaptive radiopharmaceutical therapy. Front Nucl Med. 2026;6:1935247.

31

Chouin N, Bardies M. Alpha-particle microdosimetry. Curr Radiopharm. 2011;4:266-280.

32

Mansouri Z, Salimi Y, Akhavanallaf A, et al. Deep transformer-based personalized dosimetry from SPECT/CT images: a hybrid approach for [177Lu]Lu-DOTATATE radiopharmaceutical therapy. Eur J Nucl Med Mol Imaging. 2024;51:1516-1529.

33

Koniar H, Miller C, Rahmim A, Schaffer P, Uribe C. A GATE simulation study for dosimetry in cancer cell and micrometastasis from the 225Ac decay chain. EJNMMI Phys. 2023;10:46.

34

Woo SK. The role of artificial intelligence in advancing theranostics dosimetry for cancer therapy: a review. Nucl Med Mol Imaging. 2025;59:329-341.

35

Berumen F, Ouellet S, Enger S, Beaulieu L. Aleatoric and epistemic uncertainty extraction of patient-specific deep learning-based dose predictions in LDR prostate brachytherapy. Phys Med Biol. 2024;69:085026.

36

Shanmugiah J, Kim JS. Personalised dosimetry in nuclear medicine: bridging physics, biology and AI for next generation radiopharmaceutical therapy. Nucl Med Mol Imaging. 2026;60:221-249.

37

Xue S, Gafita A, Zhao Y, et al. Pre-therapy PET-based voxel-wise dosimetry prediction by characterizing intra-organ heterogeneity in PSMA-directed radiopharmaceutical theranostics. Eur J Nucl Med Mol Imaging. 2024;51:3450-3460.

38

Xue S, Gafita A, Dong C, et al. Application of machine learning to pretherapeutically estimate dosimetry in men with advanced prostate cancer treated with 177Lu-PSMA I&T therapy. Eur J Nucl Med Mol Imaging. 2022;49:4064-4072.

39

Yazdani E, Geramifar P, Karamzade-Ziarati N, Sadeghi M, Amini P, Rahmim A. Radiomics and artificial intelligence in radiotheranostics: a review of applications for radioligands targeting somatostatin receptors and prostate-specific membrane antigens. Diagnostics (Basel). 2024;14:181.

40

Yazdani E, Neizehbaz A, Karamzade-Ziarati N, et al. Transforming [177Lu]Lu-PSMA-617 treatment planning: machine learning-based radiodosiomics and Swin UNETR using pretherapy PSMA positron emission tomography/computed tomography (PET/CT). Med Phys. 2025;52:e70030.

41

Yadav S, Lowery B, Tuchayi AM, et al. Impact of posttreatment SPECT/CT on patient management during 177Lu-PSMA-617 radiopharmaceutical therapy. J Nucl Med. 2024;65:1395-1401.

42

Gutsche R, Gülmüs G, Mottaghy FM, et al. Multicentric 68Ga-PSMA PET radiomics for treatment response assessment of 177Lu-PSMA-617 radioligand therapy in patients with metastatic castration-resistant prostate cancer. Front Nucl Med. 2023;3:1234853.

43

Warfvinge CF, Gustafsson J, Roth D, et al. Relationship between absorbed dose and response in neuroendocrine tumors treated with [177Lu]Lu-DOTATATE. J Nucl Med. 2024;65:1070-1075.

44

Kelly BS, Judge C, Bollard SM, et al. Radiology artificial intelligence: a systematic review and evaluation of methods (RAISE). Eur Radiol. 2022;32:7998-8007. Erratum in: Eur Radiol. 2022;32:8054.

45

Poel R, Rüfenacht E, Hermann E, et al. The predictive value of segmentation metrics on dosimetry in organs at risk of the brain. Med Image Anal. 2021;73:102161.

46

Hussein M, Clark CH, Nisbet A. Challenges in calculation of the gamma index in radiotherapy - towards good practice. Phys Med. 2017;36:1-11.

47

Kompa B, Snoek J, Beam AL. Second opinion needed: communicating uncertainty in medical machine learning. NPJ Digit Med. 2021;4:4.

48

Chen H, Tie Y, Cao X, Young GS, Xu X. Strategies for creation of data reserve and stress testing of medical AI products. BMJ Health Care Inform. 2024;31:e101184.